Shubra El Kheima • Qalyubia • Egypt • 50 Hz

CE Certified Industrial Oil Transformer Manufacturer & Factory for the Shubra El Kheima market

IEC 60076 oil-immersed distribution and power transformers engineered for factories, utilities and EPC projects across Greater Cairo — with CE documentation, routine test reports and export-ready support.

Contact Us

Factory product range

CE-Certified Oil Transformer Products for Shubra El Kheima Industry

Eight production families cover utility distribution, industrial plants, pad-mounted underground networks and larger power applications. Each inquiry can be reviewed against 50 Hz operation, project-specific impedance, loss targets, vector group, tap range, cooling method and Egyptian site conditions.

CE S11 three phase oil immersed distribution transformer 10kV 20kV 35kV CE · Distribution

C CE S11 10KV 20KV 35KV 50KVA 100KVA 150KVA 200KVA 250KVA 3 Phase Oil-Immersed Transformer for Electric Power Distribution

Recommended for industrial feeders, workshops and commercial distribution where a compact low-loss oil transformer is required.

  • 50–250 kVA
  • 10–35 kV class
  • 3 phase
MV HV three phase loop feed pad mounted transformer for industrial power Pad-mounted

C CE MV&HV 50/60HZ 300KVA 500KVA 630KVA 700KVA 10KV 15KV 20KV 35KV 3 Phase Loop Feed Pad Mounted Transformer for Industrial

Loop-feed pad-mounted configuration for underground distribution, industrial parks and sites where a secure outdoor footprint matters.

  • 300–700 kVA
  • Loop feed
  • 10–35 kV
CE certified oil type dead front pad mounted three phase transformer Dead-front

C Certified Oil-Type Cooper 75-2500kva Pad Mounted Transformer 6kv-34.5kv 50/60hz Dead Front Three Phases

Dead-front compartment design for projects requesting additional safety separation between live parts and operating personnel.

  • 75–2500 kVA
  • 6–34.5 kV
  • Dead-front
CE three phase oil immersed power transformer 100kVA to 1000kVA Power transformer

C CE 50/60HZ 100KVA 300KVA 500KVA 630KVA 1000KVA 10KV 20KV 35KV 3 Phase Oil Immersed Power Transformer for Power Supplies

Oil-immersed three-phase power transformer for plant substations, utilities and larger industrial power supplies.

  • 100–1000 kVA
  • 10–35 kV
  • Power supply
CE S11 three phase oil immersed transformer 6kV to 35kV for distribution system Distribution

C CE S11 50/60HZ 6KV 10KV 15KV 20KV 35KV 100KVA 300KVA 3 Phase Oil Immersed Transformer 50KVA 33KV for Distribution System

A flexible S11 distribution series for replacement projects, new factory buildings and utility distribution networks.

  • 50–300 kVA
  • 6–35 kV
  • S11 series
CE certification IEEE standard 33kV oil immersed three phase power transformer IEEE / CE

C CE Certification IEEE Standard 50/60HZ S11 Three Phase 33KV Oil Immersed Power High Voltage Transformer for Industrial

For industrial procurement teams requesting IEEE-related documentation and 33 kV class oil-immersed power transformer designs.

  • 33 kV class
  • IEEE reference
  • Industrial
S11 three phase oil transformer 10kVA to 50000kVA for power distribution Wide range

C CE MH&HV 50/60HZ 10KVA-50000KVA 10KV 15KV 20KV 35KV Three Phase S11 Oil Transformer for Electric Power Distribution

Broad S11 oil transformer range for utility distribution, industrial projects and step-down substations.

  • 10–50000 kVA
  • 10–35 kV
  • 50 / 60 Hz
ANSI single phase pole mounted industrial power transformer 15kVA to 100kVA Pole-mounted

ANSI 50/60HZ 6KV 10KV 15KV 20KV 35KV 15KVA 25KVA 50KVA 100KVA Single Phase Pole Mounted Transformers for Industrial Power Supply

Single-phase pole-mounted transformer option for rural feeders, auxiliary industrial loads and distributed networks.

  • 15–100 kVA
  • Single phase
  • Pole-mounted

Factory evidence

Numbers Buyers Can Audit Before They Release a PO

Procurement in Shubra El Kheima is rarely only a price comparison. Buyers need evidence of production capability, test discipline, documentation and export reliability.

20+
Years of team experience in transformer design and supply
500 kV
Maximum voltage class covered by the wider product portfolio
6,847 m²
Verified production floorspace for transformer manufacturing
50+
R&D and technical engineers supporting project specifications
211
Qualified supply-chain partners for materials and components
24 h
Target engineer response for technical and after-sales questions

Shubra El Kheima market intelligence

What Industrial Buyers in Shubra El Kheima Actually Need from an Oil Transformer Factory

Shubra El Kheima is one of the industrial heartlands of Qalyubia and Greater Cairo. Factories, warehouses, food-processing operations, metalworking plants, chemical facilities, water utilities and commercial developments all depend on reliable medium-voltage distribution. For procurement teams, an oil transformer is not simply a kVA rating; it is a long-life asset that affects production continuity, energy losses, maintenance planning and grid compliance.

Most buyers arriving through a search for a CE certified industrial oil transformer manufacturer are trying to reduce risk. They want to know whether the supplier is a real factory, whether the unit can operate on a 50 Hz Egyptian network, whether test reports will be accepted by consultants, and whether documentation will be complete enough for utility review. That is why this page focuses on verifiable factory data, product fit, localized application scenarios and procurement questions rather than generic marketing claims.

For Shubra El Kheima projects, specifications commonly require oil-immersed distribution transformers with 11 kV or 22 kV primary voltage, 0.4 kV secondary voltage and 50 Hz frequency. Final voltage ratios, vector groups, impedance, taps and losses must always be confirmed against the local utility or consultant’s design. A CE-certified factory can support the technical file, but the transformer still needs to match the actual network.

The right sourcing approach is to shortlist a manufacturer that can provide CE documentation, IEC or IEEE test evidence, OEM/ODM customization, export packing and responsive after-sales support. The product pages below are the fastest starting point, but the real value comes from sending a complete specification so the factory can review it technically.

Local procurement priorities at a glance

Illustrative decision weighting from our industrial project reviews, not a formal Egyptian standard.

Technical compliance32%
Total owning cost28%
Delivery certainty20%
After-sales support20%

A strong transformer quotation should include loss values, tap range, vector group, applicable standard, routine test scope, drawings, packing method and document language.

Localized applications

Where Oil Transformers Fit in the Shubra El Kheima Industrial Ecosystem

Different loads require different transformer priorities. These scenarios help buyers connect product selection with real operating conditions around Qalyubia and Greater Cairo.

Industrial production lines

Oil-immersed distribution transformers feed workshops, motors, compressors and production lines. For Shubra El Kheima factories, low loss levels and stable voltage regulation can reduce operating cost and protect machinery from frequent voltage dips.

Water treatment and pumping

Pumping stations and water-treatment facilities need transformers that handle continuous operation, high ambient temperatures and dust. Oil-filled designs with well-controlled cooling and sealed tanks are often preferred for outdoor or semi-enclosed installations.

Food processing and cold storage

Cold rooms, refrigeration plants and food lines are sensitive to outages. A properly rated oil transformer with suitable overload capability and documented temperature-rise performance supports continuous operation and planned maintenance.

Cement, metals and chemicals

Heavy industrial plants often need larger oil-immersed power transformers and careful attention to motor starting, harmonics, impedance and cooling. Factory engineering review is essential before fixing the final design.

Commercial and mixed-use sites

For warehouses, retail centers and mixed-use buildings, pad-mounted or compact oil transformer solutions save space and simplify outdoor installation. Enclosure finish, lock type and cable entry should be specified for local site practice.

Utility and distributed generation

Distribution utilities and captive generation projects need clear test reports, consistent nameplates and grid-compatible designs. Where renewable generation is connected, transformer impedance and protection coordination deserve early review.

Localized trends

What Is Changing in Transformer Procurement Around Qalyubia

Egypt’s grid modernization, industrial expansion and energy-efficiency priorities are changing how buyers evaluate oil transformer quotations. The following trends are especially relevant for Shubra El Kheima projects.

Total owning cost over lowest price

No-load and load losses now receive closer scrutiny because energy costs accumulate over decades. Buyers increasingly ask for loss values, impedance and efficiency data in the quotation, not only the initial price.

High ambient and dust resilience

Shubra El Kheima’s hot, dusty environment places emphasis on cooling design, sealing, paint finish, oil preservation and maintenance access. Buyers should disclose ambient temperature and installation exposure clearly.

Compliance evidence and traceability

Consultants and EPC contractors want traceable documents: routine test reports, nameplate drawings, CE certificates, ISO system certificates and packing lists. A factory with document discipline reduces approval friction.

50 Hz network compatibility

Frequency, voltage ratio and vector group must match the Egyptian network. A supplier that understands 50 Hz practice can avoid redesign delays when the project requires 11 kV, 22 kV or another local voltage class.

Space-saving and pad-mounted designs

Industrial land and urban sites often constrain switchyard space. Pad-mounted and compact configurations can reduce civil works, shorten installation time and improve site security.

Faster response after award

Projects increasingly require quick drawing approval, transparent production updates and reliable spare-parts information. A factory with dedicated technical staff and export logistics is better placed to support compressed schedules.

Manufacturer advantages

Why Buyers Shortlist Jiangsu Wisegj Power for Oil Transformer Projects

Our strength is not a single product model. It is the combination of engineering review, controlled production, test documentation and export experience that makes a factory quotation easier to defend internally.

Verified factory capacity

6,847 m² of verified production floorspace covering winding, core assembly, drying, tanking and test preparation.

In-house routine testing

Winding resistance, ratio, vector group, impedance, load loss, no-load loss and dielectric tests can be documented per unit.

CE and ISO systems

CE certificates for relevant transformer families, supported by ISO 9001, ISO 14001 and ISO 45001 management systems.

Design customization

OEM, ODM, design-based and sample-based customization for ratings, vector group, impedance, taps, bushings, cooling and finish.

Supply-chain depth

211 qualified supply-chain partners support stable access to silicon steel, copper, bushings and key transformer components.

Documentation discipline

GA drawings, nameplate drafts, test reports and O&M manuals can be supplied in English for consultant and utility review.

Export logistics

Seaworthy packing, shock indicators and support for FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP terms.

24-hour engineer response

Technical and after-sales questions are routed to qualified staff, with a target response within one working day.

Wisegj transformer manufacturing facility and production workshop

Audit-ready factory

A Transformer Factory in Suzhou, Built for Export Compliance

Jiangsu Wisegj Power Co., Ltd. designs, assembles and exports medium- and high-voltage equipment from 220 V up to 500 kV, including oil-immersed distribution transformers, pad-mounted transformers, power transformers, dry-type transformers and compact substations. The team brings more than 20 years of hands-on transformer experience and supports buyers who need a factory, not only a trading channel.

Production capability, floorspace and quality inspection have been verified onsite by TÜV Rheinland, an independent third-party inspection body. We also serve Fortune 500 companies, maintain full industry certificates and inspect finished products before shipment. For Shubra El Kheima buyers, this means a quotation can be supported with factory evidence, test documentation and an export process that is easier to audit.

Project teams can request: GA drawings, nameplate drafts, routine test reports, CE and ISO certificate copies, packing plans and commercial terms. Third-party witness inspection before dispatch is welcome.

Certification and compliance

Certificates Procurement Teams Can Verify

Certificate numbers are listed so compliance teams can check them directly with the issuing bodies. Always confirm that the certificate scope matches the exact transformer rating, voltage class and configuration in your inquiry.

CE

Oil-Immersed Power Transformer

Certificate No. 3N230310.JYTU038 · relevant to oil-immersed power transformer configurations within the certified scope.

CE

Oil-Immersed Transformer

Certificate No. M.2025.206.C121882 · confirm the certificate scope for the ordered rating and design before approval.

ISO 9001

Quality Management System

Certificate No. 62824Q6052R0S · supports production and quality-control processes for transformer manufacturing.

ISO 14001 / 45001

Environmental, Health & Safety

ISO 14001 No. 62824E6053R0S and ISO 45001 No. 62824S6054R0S support responsible factory operations.

RFQ checklist

How to Specify an Oil Transformer for Shubra El Kheima: A 9-Point Checklist

A complete RFQ reduces clarification rounds and helps the factory return a compliant design with stable loss values and realistic lead time.

1. Core electrical data

  • Rated power in kVA or MVA, with normal and emergency operating assumptions.
  • Primary and secondary voltage, such as 11 kV / 0.4 kV or 22 kV / 0.4 kV, confirmed by your consultant.
  • Frequency: 50 Hz for the Egyptian network, with any dual-frequency requirement stated clearly.

2. Operating environment

  • Maximum ambient temperature, altitude, humidity, dust exposure and indoor or outdoor installation.
  • Required cooling method, such as ONAN or ONAF, and any expected overload profile.
  • Insulating fluid preference: mineral oil or natural ester, subject to project and utility approval.

3. Compliance and QA

  • Vector group, impedance, tap range and neutral arrangement, all confirmed against the network study.
  • Loss limits or total owning cost evaluation, plus applicable IEC, IEEE or utility specification.
  • Test scope, third-party inspection, drawing approval, nameplate language and packing requirements.

Shipping and inspection

Export Logistics for Egypt-Bound Oil Transformer Orders

Oil transformers require careful packing, lifting planning and document control. For Shubra El Kheima deliveries, the transport route is usually arranged through Mediterranean ports such as Alexandria, Damietta or Port Said, subject to the final project logistics plan.

Export packing

  • Seaworthy crating and protection suitable for multimodal transport.
  • Shock and tilt indicators can be arranged for high-value units.
  • Marking, packing list and lifting instructions supplied for site handling.

Inspection before dispatch

  • Routine tests recorded per serial number before shipment.
  • Buyer or third-party witness inspection is welcome before packing.
  • Photographs, test reports and inspection records can be shared for approval.

Commercial terms

  • Incoterms supported include FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP.
  • Payment methods can include T/T, L/C, D/P and D/A by agreement.
  • Quotation currencies include USD, EUR, GBP, CAD and AUD among other major currencies.

Local procurement FAQ

Questions Shubra El Kheima Buyers Ask Before Ordering Oil Transformers

These are the practical questions that often decide whether a factory inquiry can move to drawing approval and purchase order.

Which oil transformer type is best for a factory in Shubra El Kheima?

For most factory distribution needs, a three-phase oil-immersed distribution transformer is the starting point, with rating and voltage selected from the load study. If the installation needs an outdoor, tamper-resistant unit with underground cable feed, a pad-mounted transformer may be more suitable. For larger plant substations, a power transformer should be reviewed. The final choice must match the network voltage, load profile, space, protection scheme and utility requirements.

Can you supply 50 Hz, 11 kV / 0.4 kV or 22 kV / 0.4 kV designs?

Yes. Oil transformer designs can be quoted for 50 Hz operation and common medium-voltage ratios such as 11 kV / 0.4 kV or 22 kV / 0.4 kV, subject to the exact specification. Please provide the final voltage ratio, vector group, impedance, tap range, rated power and any utility-specific requirements so the design can be confirmed correctly.

Is CE certification sufficient for Egypt, or are other approvals needed?

CE certification supports conformity evidence, but it is not a substitute for the project’s Egyptian utility or consultant approval process. Buyers should confirm the applicable grid code, technical specification and document requirements with the local authority or engineer. We can supply CE, ISO, routine test reports, drawings and other requested documents for the approval file.

How do you handle high ambient temperature and dusty industrial sites?

Ambient temperature, altitude, installation exposure and expected loading should be stated in the inquiry. For hot and dusty environments, the factory can review cooling method, temperature-rise assumptions, tank finish, sealing, bushings, cable entry and maintenance access. These details should be agreed before production because they directly affect the transformer design and guaranteed performance.

What routine tests are performed before shipment?

Every oil transformer can receive routine tests including winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied voltage and induced voltage tests. Oil dielectric strength testing is included for liquid-filled units. Type test reports can be discussed, and third-party witness inspection is welcome before packing.

Can the transformer be customized for our consultant’s specification?

Yes. OEM, ODM, design-based and sample-based customization is available for ratings, vector group, impedance, tap range, bushing configuration, cooling method, insulating fluid, enclosure color, nameplate language and document package. The most efficient approach is to send the tender specification or datasheet with your inquiry so the engineering team can identify deviations early.

How are transformers packed and shipped to Egypt?

Export packing is planned around the transformer size, transport route and site handling method. Seaworthy crating, lifting points, marking, packing lists and optional shock indicators can be arranged. Egypt-bound orders are commonly routed through Mediterranean ports, but the final Incoterm, port, shipping schedule and document set should be confirmed at quotation stage.

What information should I send to receive a fast and accurate quotation?

Send the rated power, primary and secondary voltage, frequency, phase, vector group, impedance, tap range, cooling method, insulating fluid, loss limits, applicable standard, site ambient conditions, altitude, required test reports and delivery terms. If you have a single-line diagram, datasheet, tender document or nameplate photo, include it. Our engineers can then review the specification and respond with a technical proposal rather than a generic price.

Ready to Review an Oil Transformer Specification for the Shubra El Kheima Market?

Send your datasheet, single-line diagram or tender document. A transformer engineer can review the requirements for 50 Hz operation, voltage ratio, losses, cooling, test scope and export packing before a final quotation is issued.

Contact Us

For a faster technical response, include rated power, voltage ratio, frequency, vector group, impedance, tap range, loss targets, site ambient conditions and required documentation.