Jiangsu Wisegj Power Co., Ltd. transformer manufacturing facility

Top Sale Transformers

Factory-Direct Transformer Best Sellers

Proven Transformer Designs for Utilities, EPCs and Industrial Buyers

Jiangsu Wisegj Power Co., Ltd. supplies top-selling distribution and power transformers for underground networks, renewable energy projects, commercial buildings, industrial plants and utility substations. The Top Sale range brings together the models most frequently requested by overseas procurement teams: three phase pad mounted transformers, single phase pad mounted transformers, oil immersed distribution transformers, dry type transformers, large power transformers and compact substations.

Each project is reviewed against the destination grid code, frequency, ambient conditions and installation method before quotation. Units can be configured to IEC 60076, IEEE C57.12, ANSI or project-specific requirements, with documented routine tests and English-language drawings supplied for engineering approval.

  • Voltage range from 220 V to 500 kV
  • IEC and ANSI/IEEE design options
  • Routine test report for every serial number
  • OEM, ODM and project-specific customization
  • ISO 9001, ISO 14001 and ISO 45001 systems
  • Export packing and documentation support

Top Sale Range at a Glance

  • Distribution transformers: 10 kVA to 5,000 kVA for residential, commercial and industrial networks.
  • Voltage classes: 220 V, 6 kV, 10 kV, 15 kV, 20 kV, 35 kV, 69 kV, 110 kV, 220 kV and higher project-specific levels.
  • Standards: IEC 60076, IEEE C57.12, ANSI, local utility specifications and CE-marked product lines.
  • Quality evidence: routine tests, oil dielectric tests, material traceability and third-party witness inspection on request.
  • Export experience: sea-worthy packing, Incoterms support and documentation for projects across five continents.
Top Sale Products

Transformer Models Buyers Request Most Often

These product families are frequently selected for utility distribution, renewable interconnection and industrial power projects. Ratings, losses, impedance, tappings and accessories are confirmed against your datasheet before production.

Three phase pad mounted transformer for underground distribution Pad Mounted

Three Phase Pad Mounted Transformer

Compartmental, tamper-resistant units for underground distribution at commercial sites, data centers, campuses and renewable projects.

  • Rating100 – 5,000 kVA
  • PrimaryUp to 35 kV
  • StandardIEC / IEEE
Loop / Radial Dead-front
Three phase loop feed pad mounted transformer Loop Feed

Three Phase Loop Feed Pad Mounted Transformer

Designed for utility underground loops where continuous supply and fast isolation are important for maintenance and fault recovery.

  • Rating300 – 2,500 kVA
  • Voltage10 – 35 kV
  • FeedLoop / radial
Utility Network Tamper-resistant
ANSI standard three phase pad mounted transformer substation ANSI

ANSI Pad Mounted Transformer Substation

ANSI-style configuration for North American utilities and commercial projects, with options for loop feed, bayonet fusing and dead-front terminations.

  • Rating500 – 2,500 kVA
  • Voltage12.47 / 13.8 / 34.5 kV
  • StandardIEEE C57.12
North America CE Option
Oil immersed distribution transformer for utility networks Oil Immersed

Oil Immersed Distribution Transformer

Hermetically sealed distribution transformers with CRGO or amorphous cores for low-loss utility networks and industrial distribution systems.

  • Rating30 – 2,500 kVA
  • Primary6 – 35 kV
  • VectorDyn11 / Yyn0
Low Loss Corrugated Tank
Oil type pad mounted transformer for power generation and distribution Oil Type

Oil Type Pad Mounted Transformer

Outdoor oil-filled pad mounted units for power generation, industrial facilities and distribution systems requiring a compact footprint.

  • Rating75 – 2,500 kVA
  • Voltage10 – 35 kV
  • FluidMineral / ester
Outdoor CE Certified
High voltage oil immersed power transformer for transmission substations Up to 220 kV

High Voltage Power Transformer

Oil immersed power transformers for transmission, generation step-up and grid interconnection, engineered to project loss and impedance targets.

  • Voltage69 – 220 kV
  • CoolingONAN / ONAF
  • TapOLTC / NLTC
Utility Sub Tested
Large power transformer for high capacity substations Large Power

Large Power Transformer

High-capacity transformer designs for utility, industrial and generation projects where loss performance, thermal behavior and reliability are critical.

  • CapacityUp to 370 MVA
  • Voltage69 – 220 kV+
  • DesignProject-based
Low Loss ONAF / OFAF
Medium voltage power transformer for distribution substations Medium Voltage

Medium Voltage Power Transformer

Distribution substation transformer for industrial plants, commercial infrastructure and renewable projects with customized vector groups and tappings.

  • Capacity1 – 20 MVA
  • Voltage6 – 35 kV
  • CustomVector / losses
CE Certified Renewables
Transformer Categories

Product Categories Available for Top Sale Procurement

Use these categories to shortlist equipment before sharing your electrical specification. Our engineers can review the datasheet, confirm the applicable standard and recommend a compliant configuration.

Pad Mounted Transformers

Three phase and single phase pad mounted units for underground residential, commercial and utility distribution systems.

Oil Immersed Transformers

Distribution and power transformers with mineral oil or natural ester fluid, sealed tank options and low-loss core designs.

Dry Type Transformers

Cast resin, oil-free transformers for indoor installations where fire safety, low maintenance and close-to-load placement matter.

Power Transformers

Medium and high voltage power transformers for transmission substations, generation step-up and large industrial power supply.

Compact Substations

Factory-assembled MV switchgear, transformer and LV distribution in a prefabricated enclosure for faster site commissioning.

Switchgear & Voltage Control

High and low voltage switchgear, voltage stabilizers and step voltage regulators for complete distribution packages.

Why Buyers Choose Wisegj

Engineering Evidence Behind Our Top Sale Transformers

Overseas buyers need more than a product list. We provide design review, traceable production data, test evidence and export documentation so procurement teams can verify compliance before shipment.

Verified Factory Capacity

6,847 m² of inspected production space with dedicated winding, core assembly, drying, tanking, testing and packing areas.

In-House Routine Testing

Ratio, resistance, loss, impedance, dielectric and oil BDV tests are documented against each serial number.

Project-Specific Design

Ratings, vector group, impedance, tappings, bushings, cooling method and enclosure are adapted to your utility specification.

Export Logistics

Sea-worthy packing, shock indicators, loading supervision and Incoterms support from EXW to DDP.

Certified Management Systems

ISO 9001, ISO 14001 and ISO 45001 management systems support consistent quality, safety and environmental control.

Complete English Documentation

GA drawings, nameplate drafts, routine test reports, packing lists and O&M documents are prepared for buyer review.

Company Introduction

Inside Jiangsu Wisegj Power Co., Ltd.

From core and coil assembly to final testing and export packing, our team controls the production steps that affect transformer reliability, loss performance and delivery confidence.

Jiangsu Wisegj Power Co., Ltd. supports utility and EPC buyers with factory inspection, design clarification, documentation review and export coordination. Production capability, floorspace and quality inspection records have been assessed by independent third-party inspection bodies, helping overseas procurement teams verify supplier reliability before placing an order.

Quality, Standards & Compliance

Verifiable Quality Controls for Top Sale Transformer Orders

Our quality approach is built around documented design inputs, controlled production and measurable test results. Certificate numbers and test reports can be reviewed by your compliance team during the approval process.

ISO 9001

Quality Management

Production planning, in-process inspection and final testing follow controlled quality procedures. Certificate No. 62824Q6052R0S.

ISO 14001

Environmental Control

Environmental management procedures support responsible handling of oil, materials and workshop waste. Certificate No. 62824E6053R0S.

ISO 45001

Health & Safety

Occupational health and safety controls support stable production and safer handling of heavy transformer components. Certificate No. 62824S6054R0S.

CE

Market Compliance

CE certificates cover selected oil immersed, dry type and compact substation product lines, with certificate numbers available for verification.

Factory Tests Normally Included

The exact test plan depends on product type and applicable standard. For liquid-filled transformers, routine testing commonly includes the following checkpoints.

  • Winding resistance
  • Voltage ratio & vector group
  • Impedance & load loss
  • No-load loss & current
  • Applied voltage withstand
  • Induced voltage withstand
  • Oil dielectric strength
  • Tap changer operation check
  • Visual & dimensional inspection
Selection Guide

How to Shortlist the Right Top Sale Transformer

Use this comparison as a starting point for technical discussion. Final selection should consider load profile, fault level, altitude, ambient temperature, installation space, local grid code and efficiency requirements.

Transformer TypeTypical RatingInstallationBest ApplicationKey Standards
Three Phase Pad Mounted100 – 5,000 kVA, up to 35 kVOutdoor, ground pad, underground cable feedCommercial sites, solar farms, data centers, campusesIEC 60076, IEEE C57.12.34
Single Phase Pad Mounted10 – 250 kVAOutdoor, residential easementsHousing developments, rural underground loopsIEEE C57.12.38
Oil Immersed Distribution30 – 2,500 kVA, 6 – 35 kVOutdoor platform, pole or substationUtility distribution, industrial plants, minesIEC 60076-1/-2/-3
Cast Resin Dry Type30 – 2,500 kVA, up to 35 kVIndoor, close to the loadHospitals, high-rises, tunnels, marine, fire-sensitive areasIEC 60076-11
Power TransformerMedium and high voltage classesOutdoor substationTransmission, generation step-up, grid interconnectionIEC 60076, IEEE C57.12.00
Compact Substation100 – 2,500 kVA, 10 – 35 kVOutdoor, prefabricated enclosureRenewables, urban networks, temporary or fast-track projectsIEC 62271-202

Ranges shown are typical reference ranges. Ratings outside these values can be engineered on request. Sharing the final single-line diagram, load calculation and local standard helps our engineers return a compliant proposal faster.

Export Support

Procurement Support for Overseas Buyers

Top Sale transformers are exported to utilities, EPC contractors, distributors and industrial end users across the Americas, Europe, Africa, the Middle East and Asia. We align documentation, packing and delivery terms with the destination market.

Delivery Terms

FOB, CFR, CIF, EXW, FCA, CIP, CPT, DDP and other agreed Incoterms can be quoted according to project logistics.

Export Documentation

Commercial invoice, packing list, bill of lading, certificate of origin and test documentation can be prepared for customs and project handover.

Technical Documents

GA drawings, nameplate drafts, routine test reports, installation guidance and O&M documents are supplied in English for review.

Packing & Protection

Export-grade packing, moisture protection, shock indicators and loading supervision help reduce transport risk for heavy equipment.

Customization

Voltage, frequency, vector group, impedance, enclosure color, accessories and nameplate data can be adapted to your project requirements.

Pre-Shipment Review

Buyers and third-party inspectors are welcome to review drawings, witness routine tests and inspect finished units before shipment.

Payment Methods

T/T, L/C, D/P and D/A can be discussed according to contract value and destination requirements.

Currencies

USD, EUR, GBP, CAD, AUD and other major currencies may be considered during commercial negotiation.

Inspection

Third-party witness testing and pre-shipment inspection are supported for buyer quality assurance programs.

FAQ

Questions Overseas Buyers Ask About Top Sale Transformers

Clear answers for procurement teams preparing a technical enquiry, datasheet or tender package.

What types of transformers are included in the Top Sale range?
The Top Sale range focuses on fast-moving utility and industrial equipment: three phase pad mounted transformers, single phase pad mounted transformers, oil immersed distribution transformers, dry type transformers, oil immersed power transformers and compact substations. Each unit is configured for the destination market and project specification rather than being treated as fixed catalogue stock.
Which standards can Jiangsu Wisegj Power Co., Ltd. design transformers to?
Transformers can be designed and tested to IEC 60076, IEEE C57.12, ANSI requirements and project-specific utility specifications. Insulating fluid, vector group, impedance, tap range, bushings, cooling method and enclosure can be adjusted for 50 Hz or 60 Hz grids and local installation practice.
Can a top-sale transformer be customized for a specific project?
Yes. OEM, ODM, design-based and sample-based customization are available. Typical customization includes rated power, primary and secondary voltage, frequency, vector group, impedance, tap changer, cooling method, insulating fluid, enclosure finish, accessories and nameplate language.
What testing documents are supplied before shipment?
Routine factory test reports are supplied for each unit and normally include winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied voltage and induced voltage tests, plus oil dielectric strength testing for liquid-filled transformers. Third-party witness inspection can be arranged when required.
Which export terms and payment methods are supported?
Common export terms include FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP. Payment methods such as T/T, L/C, D/P and D/A can be discussed according to the order value, destination and contract terms. Documents and nameplates are normally supplied in English.

Request a Top Sale Transformer Quotation

Share your rated power, primary and secondary voltage, frequency, vector group, impedance, cooling method, applicable standard and delivery destination. Our engineers will review the specification and respond with a compliant configuration.

[email protected]
Inquire Now