High-voltage oil immersed power transformer with radiators
Product Category

Power Transformer

Jiangsu Wisegj Power Co., Ltd.

Oil-immersed and high-voltage power transformers engineered to IEC 60076 and IEEE C57.12 for utilities, EPC contractors and industrial power projects.

6 kV – 500 kV IEC / IEEE Routine tested
Built for Procurement Teams

Power Transformers Engineered for Reliable Grid Performance

Jiangsu Wisegj Power Co., Ltd. supplies oil-immersed power transformers from 300 kVA to 31.5 MVA and voltage classes from 6 kV to 500 kV. Every project is reviewed by transformer engineers, manufactured under controlled quality systems and supplied with routine test reports for utility, industrial and renewable applications.

Standards & Compliance

Designed to IEC 60076 and IEEE C57.12 series standards, with CE certification available for applicable product lines.

Custom Engineering

Ratings, vector group, impedance, taps, cooling, bushings, enclosure finish and nameplate language adapted to your project.

Routine Testing

Winding resistance, ratio and vector group, impedance and loss, dielectric tests and oil testing documented per serial number.

Export Documentation

English GA drawings, nameplate drafts, test reports, O&M manuals and seaworthy packing documentation for overseas buyers.

Product Range

Power Transformer Product Range

Oil-immersed power and distribution transformers for utility substations, industrial plants, renewable energy projects and export markets. All models can be engineered to your voltage, frequency and loss requirements.

Oil-Immersed & High-Voltage Power Transformers

Select a standard configuration below or share your datasheet for a custom-engineered design with guaranteed losses and drawings.

31.5 MVA 35 kV oil immersed power transformer 35 kV

31.5 MVA 35 kV Oil-Immersed Power Transformer

Custom-built three-phase power transformer for utility transmission and heavy industrial substations.

  • Rating31.5 MVA
  • Primary35 kV
  • StandardIEC / IEEE
6.3 MVA 110 kV high-voltage power transformer 110 kV

6.3 MVA 110 kV High-Voltage Power Transformer

American-standard oil-immersed transformer for power distribution and grid interconnection.

  • Rating6.3 MVA
  • Primary110 kV
  • StandardIEEE C57.12
25 MVA three phase power transformer for transmission 50/60 Hz

25 MVA 35/69/110 kV Three-Phase Power Transformer

IEEE-standard MH&HV transformer with multi-voltage capability for transmission networks.

  • Rating25 MVA
  • Voltage35–110 kV
  • StandardIEEE
20 MVA 35 kV oil immersed power transformer 60 Hz

20 MVA 35 kV Oil-Immersed Power Transformer

Three-phase, 60 Hz power transformer for utility and industrial power distribution.

  • Rating20 MVA
  • Primary35 kV
  • Frequency60 Hz
6300 kVA 35 kV oil immersed transformer 35 kV

6,300 kVA 35 kV Oil-Immersed Transformer

Custom 60 Hz three-phase transformer for medium-voltage distribution and plant power supply.

  • Rating6,300 kVA
  • Primary35 kV
  • Frequency60 Hz
1250 kVA to 1600 kVA oil immersed power transformer 20 kV

1,250–1,600 kVA 20 kV Power Transformer

Oil-immersed unit with flexible low-voltage outputs for industrial and commercial networks.

  • Rating1,250–1,600 kVA
  • Primary20 kV
  • Output110–440 V
1600 kVA 35 kV oil immersed transformer 35 kV

1,600 kVA 35 kV Oil-Immersed Transformer

Custom three-phase transformer designed for stable distribution in demanding environments.

  • Rating1,600 kVA
  • Primary35 kV
  • Output110–440 V
3150 kVA 20 kV oil immersed power transformer 20 kV

3,150 kVA 20 kV Oil-Immersed Transformer

Three-phase power transformer with 50/60 Hz options for utility and industrial applications.

  • Rating3,150 kVA
  • Primary20 kV
  • Frequency50/60 Hz
800 kVA to 1000 kVA 20 kV power transformer 60 Hz

800–1,000 kVA 20 kV Power Transformer

Custom oil-immersed transformer with 220–440 V output for commercial and industrial loads.

  • Rating800–1,000 kVA
  • Primary20 kV
  • Frequency60 Hz
3150 kVA 35 kV power transformer 35 kV

3,150 kVA 35 kV Power Transformer

Three-phase 60 Hz transformer with flexible low-voltage output for overseas projects.

  • Rating3,150 kVA
  • Primary35 kV
  • Output220–440 V
S11 three phase power transformer 6 kV to 35 kV S11

S11 6–35 kV Three-Phase Power Transformer

IEEE-standard distribution transformer for 50/60 Hz utility and industrial power systems.

  • Voltage6–35 kV
  • TypeS11
  • StandardIEEE C57.12
S11 oil immersed transformer 6 kV to 35 kV IEC / IEEE

S11 6–35 kV Oil-Immersed Transformer

Robust three-phase transformer engineered for reliable distribution and low maintenance.

  • Voltage6–35 kV
  • CoolingONAN
  • StandardIEC / IEEE
500 kVA to 630 kVA 20 kV power transformer 20 kV

500–630 kVA 20 kV Power Transformer

Oil-immersed three-phase transformer with customizable output voltages for export markets.

  • Rating500–630 kVA
  • Primary20 kV
  • Output110–440 V
300 kVA to 500 kVA S11 power transformer CE

300–500 kVA 6–35 kV S11 Transformer

S11 three-phase oil-immersed transformer for distribution systems and industrial facilities.

  • Rating300–500 kVA
  • Voltage6–35 kV
  • StandardIEC 60076
2500 kVA 20 kV oil immersed power transformer 20 kV

2,500 kVA 20 kV Power Transformer

Three-phase oil-immersed transformer with multiple secondary voltages for utility projects.

  • Rating2,500 kVA
  • Primary20 kV
  • Output110–440 V
2500 kVA 10 kV IEC power transformer IEC 60076

2,500 kVA 10 kV IEC Power Transformer

Copper-winding oil-immersed transformer for industrial power supply and distribution.

  • Rating2,500 kVA
  • Primary10 kV
  • StandardIEC 60076

Ratings and configurations shown are representative. Transformers outside these ranges can be engineered to your project specification, including 50 Hz or 60 Hz operation, ONAN/ONAF cooling, OLTC/NLTC tap changers and special enclosure finishes.

Buyer's Guide

Power Transformer Technical Selection Guide

Use this quick reference to shortlist the right transformer class for your project. Our engineers will confirm the final design against your load profile, grid code and site conditions.

ApplicationTypical RatingVoltage ClassCoolingRecommended Standard
Utility transmission substation10 – 31.5 MVA35 – 110 kVONAN / ONAFIEC 60076 / IEEE C57.12
Industrial plant power supply1.6 – 20 MVA10 – 35 kVONANIEC 60076
Renewable energy interconnection1.25 – 6.3 MVA10 – 35 kVONAN / ONAFIEC 60076 / IEEE
Commercial and campus distribution0.3 – 2.5 MVA6 – 20 kVONANIEC 60076
Export projects with 60 Hz gridsCustom10 – 110 kVAccording to designIEEE C57.12 / IEC

Loss limits, impedance, tap range and temperature rise can be specified to meet local utility requirements. Share your datasheet for a design review and guaranteed performance figures.

Quality Assurance

Quality Control and Compliance for Every Power Transformer

From incoming materials to final dielectric testing, production is controlled by documented work instructions and inspection checkpoints. Third-party witness inspection is welcome.

Routine & Type Testing

Winding resistance, ratio, vector group, impedance, load and no-load loss, applied and induced voltage tests, plus oil dielectric strength for liquid-filled units.

Certified Quality Systems

ISO 9001, ISO 14001 and ISO 45001 management systems support consistent production, environmental control and workplace safety.

Material Traceability

Silicon steel, copper, bushings, tap changers and insulating oil are sourced from qualified suppliers and recorded against each production batch.

Complete Documentation

GA drawings, nameplate drafts, routine test reports, packing lists and O&M manuals are supplied in English for smooth project approval.

Third-Party Inspection

Buyer representatives and independent inspection agencies are welcome to witness factory tests, packing and final release.

Export Packing & Release

Seaworthy packing, shock indicators and complete shipping documents help protect equipment from factory to project site.

Export Support

Procurement Support for Overseas Buyers

Wisegj supports utilities, EPC contractors, distributors and industrial buyers with export documentation, flexible trade terms and engineering communication in English.

Trade Terms

FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP terms are available. Our export team coordinates booking, marking and loading according to your schedule.

Packing & Logistics

Heavy-duty export packing, weather protection and shock indication are used for transformers and accessories. Shipping documents are supplied in English.

Engineering Communication

Technical clarifications, drawings and test reports are handled by transformer engineers, not scripted sales channels. Email us at [email protected].

FAQ

Power Transformer FAQ for Procurement Teams

Answers to the technical and commercial questions we receive most often from overseas buyers.

What power transformer ratings can Wisegj supply?
We supply oil-immersed power transformers from 300 kVA to 31.5 MVA and voltage classes from 6 kV to 500 kV, including custom 50 Hz and 60 Hz designs for utility, industrial and renewable projects.
Which standards are your power transformers designed and tested to?
Power transformers are designed and tested to IEC 60076 or IEEE C57.12 series standards according to the destination market. Production runs under ISO 9001, ISO 14001 and ISO 45001 systems, with CE certification available for applicable product lines.
Can power transformers be customized for my project?
Yes. We customize ratings, vector group, impedance, tap range, cooling method, bushings, insulating fluid, enclosure finish and nameplate language. OEM, ODM and design-based customization are available.
What testing and documentation are supplied before shipment?
Each unit receives routine tests including winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied and induced voltage tests, plus oil dielectric testing for liquid-filled units. Test reports, GA drawings and O&M manuals are supplied in English.
How are power transformers packed and shipped?
Transformers are packed for seaworthy export with shock indicators and complete shipping documents. We support FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP terms with T/T, L/C, D/P and D/A payment options in major currencies.

Request a Power Transformer Catalog

Send your datasheet, tender document or application details. A transformer engineer will review the requirement and provide a compliant proposal with drawings and guaranteed performance data.

[email protected]
Get Catalog