Single Phase Pad Mounted Transformer

10-250 kVA · 5-34.5 kV primary · 120/240 V and 277/480 V secondary · IEEE C57.12.38 & IEC 60076

Product Overview

Utility-Grade Single Phase Pad Mounted Transformers for Underground Distribution

Jiangsu Wisegj Power Co., Ltd. manufactures single phase pad mounted transformers for underground residential and commercial distribution. Standard ratings cover 10, 15, 25, 37.5, 50, 75, 100, 167 and 250 kVA with primary voltages from 5 kV to 34.5 kV and secondary voltages of 120/240 V, 120/208 V, 240/480 V, 277/480 V or project-specific values. Units can be supplied with mineral oil or natural ester fluid and are engineered to IEEE C57.12.38 or IEC 60076 depending on the destination market.

Each design is reviewed by transformer engineers before quotation. Core and winding selections are made for guaranteed no-load and load losses, temperature rise and sound level. Routine tests are performed on every serial number, and test reports, GA drawings, nameplates and O&M documents are supplied in English for procurement, approval and commissioning teams.

  • 10-250 kVA, up to 34.5 kV
  • Loop feed and radial feed options
  • Dead-front, tamper-resistant enclosure
  • Bayonet fuse and weak link protection
  • Mineral oil or natural ester fluid
  • IEEE and IEC standards
Single phase pad mounted transformer with tamper-resistant enclosure
0 kVA
Maximum standard single phase rating
0 kV
Maximum primary voltage class
0 m²
Verified production floorspace
0+
R&D and technical engineers
0+
Years of team transformer experience
0
Qualified supply-chain partners
Product Range

Single Phase Pad Mounted Transformer Ratings

Common ratings are listed below for residential subdivisions, commercial sites, utility reinforcement and renewable interconnections. Custom voltage ratios, taps, fluids and enclosures can be engineered for project specifications.

10 to 25 kVA single phase pad mounted transformer for residential distribution10-25 kVA

Residential Feeder Units

Compact low-profile transformers for subdivisions, rural underground loops and street lighting circuits.

  • Rating10-25 kVA
  • Primary5-25 kV
  • StandardIEEE C57.12.38
37.5 to 75 kVA single phase pad mounted transformer for commercial distribution37.5-75 kVA

Commercial Distribution

Reliable service for commercial buildings, shopping centers, schools and small industrial loads.

  • Rating37.5-75 kVA
  • Primary15-34.5 kV
  • CoolingONAN
100 to 167 kVA single phase pad mounted transformer for utility service100-167 kVA

Community and Utility Service

High-capacity units for larger residential blocks, water treatment, EV charging hubs and utility reinforcement.

  • Rating100-167 kVA
  • Secondary120/240 V
  • FluidMineral / FR3
250 kVA single phase pad mounted transformer for custom utility projects250 kVA

Custom Project Units

Custom-engineered designs for special primary voltages, high ambient conditions, coastal corrosion protection and renewable interconnections.

  • Rating250 kVA
  • PrimaryUp to 34.5 kV
  • StandardIEC / IEEE
Technical Specifications

Specification Guide for Overseas Procurement

Use this guide for preliminary selection. Final ratings, losses, impedance, tap range, accessories and enclosure details are confirmed by our engineering team against the project datasheet.

ParameterTypical Range / OptionsProcurement Note
Rated power10-250 kVARatings outside the standard range can be reviewed as custom projects.
Primary voltage5, 10, 13.2, 13.8, 15, 20, 24.94, 34.5 kV and project-specific valuesVoltage class and BIL are confirmed for the destination grid.
Secondary voltage120/240 V, 120/208 V, 240/480 V, 277/480 V and custom valuesSecondary configuration is matched to the load and service entrance design.
Frequency50 Hz or 60 HzCore and winding design are adjusted for the specified frequency.
CoolingONANTemperature rise and ambient conditions are confirmed at design review.
Insulating fluidMineral oil or natural ester fluidFluid selection can support fire-safety or environmental requirements.
CoreCRGO silicon steel or amorphous coreCore grade is selected against no-load loss and efficiency targets.
WindingCopper or aluminumConductor material is supplied to the approved technical specification.
EfficiencyDOE 2016, EU EcoDesign or project-specific loss limitsGuaranteed losses are stated on the approved data sheet.
StandardsIEEE C57.12.38, IEEE C57.12.28 enclosure, IEC 60076The applicable standard is confirmed for each destination market.
Feed configurationLoop feed or radial feedSwitching, fusing and parking stands are configured to the network design.
Tap range2 x 2.5% or project-specificTap arrangement is confirmed against the primary voltage profile.
EnclosurePowder-coated steel or stainless-steel optionCoastal, high-humidity and high-pollution environments can be reviewed.
AccessoriesBayonet fuse, weak link, pressure relief, oil sight glass, drain valve, lifting lugs, ground padsAccessory list is fixed during drawing approval.
TestingRoutine tests per serial number; type test reports availableThird-party witness inspection can be arranged before shipment.

The information above is a preliminary selection guide. Final technical data is confirmed on the approved GA drawing, nameplate drawing and test report for each order.

Design Features

Design Features That Reduce Field Risk

Every feature is selected to support safe installation, reliable operation and efficient maintenance in underground distribution networks.

Dead-Front Compartment

Separate high-voltage and low-voltage compartments with tamper-resistant access for safer field operation.

Loop or Radial Feed

Configurations can match looped underground networks or radial service arrangements without field modification.

Bayonet Fuse Protection

Fuse and weak-link options provide coordinated protection for distribution transformers and downstream loads.

Low-Loss Core and Winding

CRGO or amorphous core options and optimized winding design help meet efficiency and loss targets.

Corrosion-Resistant Enclosure

Powder-coated steel or stainless-steel options are available for coastal, humid and polluted environments.

Complete Documentation

GA drawings, nameplate drawings, routine test reports and O&M manuals are prepared in English for project approval.

Manufacturing and Testing

Inside Production, Inspection and Export Preparation

Production is organized around documented work instructions and inspection checkpoints from core assembly through final testing, packing and loading.

Quality Assurance

Routine Tests, Certifications and Export Documentation

Each transformer is built under a documented quality management system. The production team records inspection results by serial number, and the export team prepares the technical file required by procurement, consultants and commissioning engineers.

  • Winding resistance, ratio, polarity and impedance tests
  • No-load loss, load loss and exciting current measurements
  • Applied voltage and induced voltage withstand tests
  • Oil dielectric strength testing for liquid-filled units
  • Third-party witness inspection available on request
  • English test reports, GA drawings, nameplates and O&M manuals

TÜV Rheinland has verified production capability, floorspace and onsite quality inspection for Jiangsu Wisegj Power Co., Ltd.

ISO 9001

Quality management system
Certificate No. 62824Q6052R0S

ISO 14001

Environmental management system
Certificate No. 62824E6053R0S

ISO 45001

Occupational health and safety system
Certificate No. 62824S6054R0S

CE Certification

CE documentation is available for applicable product lines, including oil-immersed transformers, dry type transformers and compact substations.

IEEE / IEC Design

Product design and testing are aligned with IEEE C57.12.38 or IEC 60076 according to the destination market.

Export Support

Seaworthy packing, shipping marks, packing lists and export documents are prepared for the agreed Incoterms.

Applications

Where Single Phase Pad Mounted Transformers Fit

These transformers are commonly specified where underground service, tamper resistance and a compact footprint are required.

Residential Subdivisions

Underground residential loops, street lighting and community distribution where low-profile equipment is preferred.

Commercial Buildings

Retail centers, offices, schools and mixed-use developments requiring reliable pad-mounted service entrances.

Light Industrial Parks

Small manufacturing units, workshops and logistics facilities with single phase distribution loads.

Solar, Storage and EV Charging

Interconnection points for distributed energy resources, storage systems and electric vehicle charging infrastructure.

Utility Reinforcement

Replacement and expansion projects where utilities need predictable lead times and documented test reports.

Water and Rural Electrification

Water treatment facilities, agricultural loads and rural electrification programs with underground service requirements.

FAQ

Technical Questions from Overseas Buyers

These answers cover common specification, testing and export questions for single phase pad mounted transformer projects.

What ratings and voltages are available for single phase pad mounted transformers?
Standard production covers 10 kVA to 250 kVA with primary voltages from 5 kV to 34.5 kV and secondary voltages such as 120/240 V, 120/208 V, 240/480 V and 277/480 V. Custom voltage ratios, taps, fluids and enclosures can be engineered on request.
Which standards do Wisegj single phase pad mounted transformers meet?
Units are designed and tested to IEEE C57.12.38 and the applicable IEEE C57.12 enclosure standards or IEC 60076 series standards, depending on the destination market and project specification.
Can the transformers be supplied for loop feed or radial feed systems?
Yes. Loop feed and radial feed configurations are available, together with dead-front compartments, bayonet fuses, weak links, pressure relief devices and other accessories selected for the project.
Do you offer OEM, ODM or project-specific customization?
Yes. We support OEM, ODM and design-based customization covering kVA rating, primary and secondary voltage, tap range, impedance, loss limits, insulating fluid, enclosure finish, nameplate language and accessory configuration.
What tests and documents are supplied before shipment?
Each unit receives routine tests including winding resistance, voltage ratio and polarity, no-load loss and current, load loss and impedance, applied voltage and induced voltage tests, plus oil dielectric strength testing where applicable. Test reports, GA drawings, nameplate drawings and O&M manuals are supplied in English.
How are the transformers packed for export?
Units are prepared with seaworthy packing, protected bushings and accessories, lifting points and moisture protection. Shipping marks, packing lists and export documents are prepared to the agreed Incoterms and destination requirements.

Request the Single Phase Pad Mounted Transformer Catalog

Share your kVA rating, primary and secondary voltage, frequency, applicable standard and site conditions. Our engineering team will review the specification and return a compliant technical proposal with drawings, guaranteed losses and test documentation requirements.

[email protected]
Get Catalog