Utility-grade distribution transformers from 30 kVA to 2,500 kVA and 6 kV to 35 kV class. Designed to IEC 60076 and ANSI/IEEE C57.12 requirements, factory tested, CE certified and export-packed by Jiangsu Wisegj Power Co., Ltd.

30–2,500 kVA 6–35 kV Class IEC 60076 ANSI/IEEE C57.12 CE Certified OEM / ODM
Product Overview

Reliable Oil Immersed Transformers for Distribution Networks

Jiangsu Wisegj Power Co., Ltd. manufactures three phase oil immersed distribution transformers for utilities, EPC contractors, industrial plants and renewable energy projects. The product family covers 30–2,500 kVA with primary voltages from 6 kV to 35 kV and low-voltage outputs configured to project requirements. Each unit is designed around documented thermal, dielectric and short-circuit performance data rather than a generic catalogue specification.

Core and winding construction uses high-grade CRGO silicon steel, electrolytic copper or aluminium conductors, vacuum oil filling and a sealed corrugated tank. Designs can follow IEC 60076 or ANSI/IEEE C57.12 practices, with optional dual-voltage, off-circuit tap changer, on-load tap changer, conservator, radiator bank and protection accessories.

  • 30–2,500 kVA, 6–35 kV class
  • ONAN / ONAF cooling, 50 / 60 Hz
  • Hermetically sealed or conservator type
  • Copper or aluminium winding options
  • Routine test report per serial number
  • Export packing and full documentation

Typical values are for reference. Final ratings, losses, impedance and dimensions are confirmed by engineering review before quotation.

Three phase oil immersed distribution transformer with corrugated tank
Technical Data

Three Phase Oil Immersed Transformer Specifications

Typical production range for distribution applications. Project-specific voltage ratios, impedance, losses, protection and accessories are engineered to the buyer's technical data sheet.

ParameterTypical Specification / Options
Model familyS11, S13, S20 or project-specific design; loss levels can be optimized to buyer requirements
Rated power30–2,500 kVA typical; higher ratings available on engineering review
Primary voltage6, 6.3, 10, 10.5, 11, 13.8, 15, 20, 22, 33, 35 kV; custom values available
Secondary voltage0.4 kV, 0.415 kV, 0.44 kV, 0.48 kV, 220/380 V, 230/400 V, 240/415 V, 277/480 V or custom
Frequency50 Hz / 60 Hz
PhaseThree phase
Vector groupDyn11, Yyn0, YNd11 or as specified
Cooling methodONAN standard; ONAF available for higher capacity or high-ambient conditions
Tap changerOff-circuit tap changer (NLTC) or on-load tap changer (OLTC)
Winding materialElectrolytic copper or aluminium, selected to technical and commercial requirements
Core materialHigh-grade CRGO silicon steel; amorphous alloy option available for low-loss requirements
Insulating fluidMineral oil standard; natural ester / FR3-type fluid available on request
Tank constructionCorrugated tank or radiator tank; hermetically sealed design optional
Protection accessoriesPressure relief valve, Buchholz relay, oil level gauge, dial thermometer, breather, silica gel and other specified items
Temperature riseStandard design or customized for ambient temperature, altitude and loading profile
Applicable standardsIEC 60076, ANSI/IEEE C57.12 series, GB/T 1094 and project-specific requirements
Factory testingRoutine tests as standard; type tests and third-party witness inspection available

Please confirm all electrical, mechanical and site parameters before order. Documents can be issued in English and other requested languages.

Design Advantages

Why Buyers Specify Wisegj Oil Immersed Transformers

Practical engineering choices that support reliability, installation efficiency and long-term operation in utility and industrial networks.

Low No-Load and Load Losses

Core and winding designs can be optimized for energy-efficiency targets, lifecycle cost or specific loss evaluation formulas.

High Short-Circuit Strength

Clamping structures, conductor selection and manufacturing controls are applied to withstand specified short-circuit forces.

Thermal Stability

Cooling surfaces and oil circulation are matched to the rated load, ambient temperature and altitude of the installation site.

Sealed and Leak-Tested Tank

Corrugated or radiator tanks are fabricated, pressure tested and surface-treated for reliable outdoor service.

Voltage and Vector Group Flexibility

Primary and secondary voltages, tap range and vector group are configured for local grid codes and project interfaces.

Export-Ready Documentation

GA drawings, nameplate drafts, routine test reports, packing lists and O&M manuals are prepared for international procurement.

Applications

Where Three Phase Oil Immersed Transformers Are Used

Oil immersed distribution transformers are widely applied where proven dielectric performance, thermal capacity and cost efficiency are required.

Utility Distribution Feeders

Step-down transformers for medium-voltage distribution networks serving residential, commercial and mixed-load areas.

Industrial Plants and Mining

Reliable power distribution for motors, process lines, pumping stations and industrial facilities with demanding load profiles.

Commercial Buildings and Data Centers

Distribution transformers for campuses, data centers and commercial facilities where thermal performance and documentation matter.

Solar, Wind and Energy Storage

Oil immersed transformers for renewable generation and energy storage projects, configured for local grid interconnection requirements.

Rural Electrification

Cost-effective distribution transformers for rural networks, public infrastructure and community electrification programs.

Infrastructure and Transportation

Power distribution for ports, railways, tunnels, water treatment facilities and other infrastructure projects.

Manufacturer Profile

A Transformer Manufacturer Built for International Procurement

Jiangsu Wisegj Power Co., Ltd. is a transformer manufacturer and exporter based in Suzhou, Jiangsu, China. The company serves utilities, EPC contractors, distributors and industrial buyers with application-focused engineering and export documentation.

20+Years of team experience in transformers
6,847 m²Verified production floorspace
50+R&D and technical engineers
211Qualified supply-chain partners
4.9/5Average buyer rating
500 kVMaximum voltage class supplied

Production capability, floorspace and quality inspection have been verified onsite by TÜV Rheinland, an independent third-party inspection body. Certificate numbers and test documents are available for buyer review.

Address: Room 1908-1, Building 1, Xinyi Plaza, No. 68 South Tiancheng Road, High-Speed Railway New City, Suzhou, Jiangsu, China. Email: [email protected].

Production & Quality

Factory Capability, Routine Testing and Export Packing

From core stacking and winding to oil processing, tanking and final electrical tests, each operation is controlled by documented work instructions and inspection checkpoints. Routine test reports are issued by serial number.

Certifications and Compliance

Documented Quality for Buyer Verification

Certificate numbers are provided for compliance review. Final product scope and applicable standards are confirmed on the project data sheet.

CE · Oil Immersed Transformer

Certificate No. M.2025.206.C121882. Applicable to the certified oil immersed transformer scope.

CE · Oil-immersed Power Transformer

Certificate No. 3N230310.JYTU038. Suitable for applicable oil-immersed power transformer projects.

ISO 9001

Quality Management System, Certificate No. 62824Q6052R0S. Production and inspection follow documented quality procedures.

ISO 14001

Environmental Management System, Certificate No. 62824E6053R0S. Environmental controls are integrated into manufacturing operations.

ISO 45001

Occupational Health and Safety Management System, Certificate No. 62824S6054R0S. Safety controls cover production activities.

TÜV Rheinland Verified

Factory capability, floorspace and quality inspection have been verified onsite by TÜV Rheinland.

Customization and Engineering Review

Configure the Transformer to Your Project Requirements

OEM, ODM and design-based customization are available. The engineering team reviews electrical parameters, site conditions and standards before confirming the guaranteed technical data.

Options Available

  • Capacity and voltage ratio
  • Vector group and impedance
  • Tap range and tap changer type
  • Cooling method and insulating fluid
  • Winding material and core type
  • Protection and monitoring accessories
  • Enclosure finish and nameplate language
  • Standards and third-party inspection requirements

Technical Data Needed for a Fast Quotation

Complete data helps our engineers return a compliant design with guaranteed losses and drawings without unnecessary clarification rounds.

  • Rated power (kVA)
  • Primary and secondary voltage
  • Frequency (50 / 60 Hz)
  • Vector group and impedance
  • Tap changer type and range
  • Cooling method and fluid
  • Applicable standard (IEC / IEEE)
  • Site altitude and ambient range
  • Loss limits or efficiency target
  • Destination port and Incoterms

Send your data sheet or tender document to [email protected].

Export Support

Packing, Documentation and Commercial Terms

Export procurement requires more than equipment. Wisegj supports shipping documents, inspection arrangements, packing protection and after-sales communication.

Seaworthy Packing

Export-grade packing with appropriate protection for sea transport, port handling and site storage.

Complete Documentation

GA drawings, nameplate drafts, routine test reports, packing lists and operation and maintenance manuals.

Flexible Incoterms

FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP terms can be quoted according to buyer requirements.

Payment Methods

T/T, L/C, D/P and D/A and other secure options can be discussed per contract and destination market.

Global Logistics

Export experience across North America, South America, Europe, the Middle East, Asia and Africa.

After-Sales Communication

Technical questions and after-sales matters receive a qualified response from the engineering and service team.

FAQ

Questions Procurement Teams Ask About Oil Immersed Transformers

Clear answers for technical buyers, compliance teams and project managers reviewing transformer specifications.

What ratings and voltages can you supply for three phase oil immersed transformers?
Wisegj typically manufactures three phase oil immersed distribution transformers from 30 kVA to 2,500 kVA with primary voltages between 6 kV and 35 kV. Secondary voltages, vector groups and impedance values are configured to the project. Higher ratings and transmission-level designs can be reviewed separately.
Which standards and certifications apply to your transformers?
Designs can follow IEC 60076 and ANSI/IEEE C57.12 series standards. CE certificates are available for oil immersed transformers, and production operates under ISO 9001, ISO 14001 and ISO 45001 management systems. Certificate numbers and test documents are provided for buyer verification.
What factory tests are performed before shipment?
Routine tests typically include winding resistance, voltage ratio and vector group, no-load loss and current, load loss and impedance, applied voltage, induced voltage and oil dielectric strength. Type test reports can be supplied where available, and third-party witness inspection is welcome.
Can the transformer be customized for a specific project?
Yes. Customization covers capacity, voltage ratio, tap changer, vector group, impedance, cooling method, winding material, insulating fluid, protection accessories, enclosure finish, documentation language and nameplate details.
How are the transformers packed and shipped?
Liquid-filled transformers are supplied with export-grade seaworthy packing, shock and impact indicators where required, and complete documentation. We support FOB, CFR, CIF, EXW, FCA, CIP, CPT and DDP terms according to project needs.
What information should buyers provide for an accurate quotation?
Please provide rated power, primary and secondary voltage, frequency, vector group, impedance, tap range, cooling method, applicable standard, altitude, ambient temperature, loss limits and destination port. Send the data sheet to [email protected] for engineering review.

Have a Specification Ready for Review?

Share your technical data sheet, tender document or single-line diagram. Our engineering team will review the requirements and respond with a compliant transformer configuration and quotation.

Email: [email protected]

Send an Inquiry