Jiangsu Wisegj Power Co., Ltd. transformer manufacturing facility
Transformer production workshop at Jiangsu Wisegj Power Co., Ltd.
About Jiangsu Wisegj Power Co., Ltd.

A Transformer Manufacturer Built for International Procurement

Jiangsu Wisegj Power Co., Ltd. designs, assembles and exports medium- and high-voltage equipment from 220 V up to 500 kV, including power transformers, distribution transformers, pad mounted transformers, dry type transformers, compact substations, switchgear, distribution boxes and voltage stabilizers.

Our engineering team brings more than 20 years of hands-on transformer experience. Every project is reviewed by engineers before quotation, manufactured under ISO 9001 quality control and shipped with full routine test reports, helping procurement teams receive equipment that matches their utility specification the first time.

  • Own production base with full industry certificates
  • 50+ engineers in R&D and technical support
  • Supplier to Fortune 500 companies
  • 24-hour pre-sale and after-sale response
  • OEM, ODM and design-based customization
  • Finished product inspection on every unit

Production capability, floorspace and quality inspection are verified onsite by TÜV Rheinland, an independent third-party inspection body.

0+
Years of team experience in transformers
0 kV
Maximum voltage class supplied
0 m²
Verified production floorspace
0+
R&D and technical engineers
0
Qualified supply-chain partners
0/5
Average buyer rating
Why Buyers Choose Jiangsu Wisegj Power Co., Ltd.

Engineering Capability You Can Audit

Every claim below is backed by third-party inspection data, certificates or documents we share with your QA team before order.

Verified Factory Capacity

6,847 m² inspected floorspace with dedicated winding, core assembly, drying, tanking and test areas.

In-House Testing

Ratio, resistance, loss, impedance, dielectric and oil BDV tests documented for each serial number.

Design Customization

Ratings, vector group, impedance, taps, bushings, cooling and enclosure adapted to utility specifications.

Export Logistics

Seaworthy packing, shock indicators and full Incoterms coverage from EXW to DDP.

Certified Systems

ISO 9001, ISO 14001 and ISO 45001 management systems, valid through 2027.

Complete Documentation

GA drawings, nameplate drafts, test reports and O&M manuals supplied in English.

211 Supply Partners

Qualified sources for silicon steel, copper, bushings and accessories secure stable lead times.

24 h Engineer Response

Technical questions and after-sales issues receive a qualified reply within one working day.

Production Strength

Inside Our Transformer Production

From core stacking to final dielectric testing, each step is controlled by documented work instructions and inspection checkpoints.

Specification Review

Engineers check ratings, standards, site altitude and ambient conditions.

Drawing Approval

GA drawing, nameplate and guaranteed losses confirmed with buyer.

Controlled Production

Core, winding, drying and tanking with in-process QC records.

Routine Testing

Full test report per unit; third-party witness testing welcome.

Packing & Shipping

Export crating, impact recorders and complete shipping documents.

Qualifications

Certifications, Standards and Traceable Compliance

Certificate numbers are listed so your compliance team can verify them directly with the issuing bodies.

ISO 9001 Quality Management

Certificate No. 62824Q6052R0S · valid 2024–2027.

ISO 14001 Environmental Management

Certificate No. 62824E6053R0S · valid 2024–2027.

ISO 45001 Health & Safety

Certificate No. 62824S6054R0S · valid 2024–2027.

TÜV Rheinland Verified

Production capability, floorspace and quality inspection verified onsite by an independent third party.

CE · Power Transformer

Oil-immersed power transformer · No. 3N230310.JYTU038 · 2023–2028.

CE · Oil Immersed Transformer

Oil immersed transformer · No. M.2025.206.C121882 · 2025–2030.

CE · Dry Type Transformer

Dry type transformer · No. FQC2530404 · 2025–2030.

CE · Compact Substation

Compact substation · No. M.2025.206.C121884 · 2025–2030.

Global Supply

Serving Utilities and EPCs Across Five Continents

Equipment is configured for local grid codes, frequency (50/60 Hz), climate and installation practice in each market.

North America

ANSI/IEEE pad mounted and pole mounted transformers for utilities, solar and commercial projects.

South America

Distribution and power transformers for mining, utilities and high-altitude installations.

Western Europe

CE-certified IEC equipment, dry type transformers and compact substations.

Middle East

High-ambient designs with enhanced cooling for desert and coastal environments.

Southeast & Central Asia

Utility distribution, industrial parks and grid expansion programs.

Africa

Rural electrification, mining and compact substations for fast deployment.

Delivery Terms

FOB, CFR, CIF, EXW, FAS, FCA, CPT, CIP, DDP, DDU and express delivery.

Payment Methods

T/T, L/C, D/P, D/A, escrow and other secure options agreed per contract.

Currencies

USD, EUR, GBP, CAD, AUD, JPY, HKD, CHF and CNY.

Buyer’s Guide

How to Choose the Right Transformer Type

A quick engineering comparison our application team uses with EPC contractors and utilities when shortlisting equipment.

Transformer TypeTypical RatingInstallationBest ApplicationKey Standards
Three Phase Pad Mounted45 – 5,000 kVA, up to 34.5 kVOutdoor, ground pad, underground cable feedCommercial sites, solar farms, data centers, campusesIEEE C57.12.34, C57.12.28
Single Phase Pad Mounted10 – 250 kVAOutdoor, residential easementsHousing developments, rural underground loopsIEEE C57.12.38
Oil Immersed Distribution30 – 2,500 kVA, 6 – 35 kVOutdoor platform, pole or substationUtility distribution, industrial plants, minesIEC 60076-1/-2/-3
Cast Resin Dry Type30 – 2,500 kVA, up to 35 kVIndoor, close to the loadHospitals, high-rises, tunnels, marine, fire-sensitive areasIEC 60076-11
Power Transformer35 – 500 kV classOutdoor substationTransmission, generation step-up, grid interconnectionIEC 60076, IEEE C57.12.00
Compact Substation100 – 2,500 kVA, 10 – 35 kVOutdoor, prefabricated enclosureRenewables, urban networks, temporary or fast-track projectsIEC 62271-202

Ranges shown are typical production ranges. Ratings outside these values can be engineered on request.

FAQ

Questions Procurement Teams Ask Us

Straight answers from our engineering and export departments.

Which standards do your transformers follow?
Equipment is designed and tested to IEC 60076 and ANSI/IEEE C57.12 series standards depending on the destination market. Product lines hold CE certificates, and production operates under ISO 9001, ISO 14001 and ISO 45001 management systems.
What voltage and capacity ranges can you supply?
The portfolio covers 220 V to 500 kV, from 10 kVA single phase pad mounted transformers for residential feeders to oil immersed power transformers for transmission substations.
Which factory tests are performed before shipment?
Every unit receives routine tests including winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied and induced voltage tests, plus oil dielectric strength testing for liquid-filled units. Type test reports are available, and third-party witness inspection is welcome.
Can transformers be customized for my project?
Yes. OEM, ODM, design-based and sample-based customization are available, covering ratings, vector group, impedance, tap range, bushing configuration, cooling method, insulating fluid, enclosure color and nameplate language.
What trade and payment terms are accepted?
We accept FOB, CFR, CIF, EXW, FCA, CIP, CPT, DDP and other Incoterms, with T/T, L/C, D/P and D/A among the payment options, in USD, EUR, GBP, CAD, AUD and other major currencies.

Technical Data Checklist for a Faster, Accurate Offer

Sharing these parameters lets our engineers return a compliant design and guaranteed losses without extra clarification rounds.

  • Rated power (kVA / MVA)
  • Primary & secondary voltage
  • Frequency (50 / 60 Hz)
  • Vector group & impedance
  • Tap changer type & range
  • Cooling method & fluid
  • Applicable standard (IEC / IEEE)
  • Site altitude & ambient range
  • Loss limits or efficiency target

Have a Specification Ready for Review?

Send your datasheet or tender documents. A transformer engineer, not a sales script, will review it and respond within one working day.

[email protected]
Send an Inquiry