ISO 9001 Quality Management
Certificate No. 62824Q6052R0S · valid 2024–2027.
Jiangsu Wisegj Power Co., Ltd. designs, assembles and exports medium- and high-voltage equipment from 220 V up to 500 kV, including power transformers, distribution transformers, pad mounted transformers, dry type transformers, compact substations, switchgear, distribution boxes and voltage stabilizers.
Our engineering team brings more than 20 years of hands-on transformer experience. Every project is reviewed by engineers before quotation, manufactured under ISO 9001 quality control and shipped with full routine test reports, helping procurement teams receive equipment that matches their utility specification the first time.
Production capability, floorspace and quality inspection are verified onsite by TÜV Rheinland, an independent third-party inspection body.
Every claim below is backed by third-party inspection data, certificates or documents we share with your QA team before order.
6,847 m² inspected floorspace with dedicated winding, core assembly, drying, tanking and test areas.
Ratio, resistance, loss, impedance, dielectric and oil BDV tests documented for each serial number.
Ratings, vector group, impedance, taps, bushings, cooling and enclosure adapted to utility specifications.
Seaworthy packing, shock indicators and full Incoterms coverage from EXW to DDP.
ISO 9001, ISO 14001 and ISO 45001 management systems, valid through 2027.
GA drawings, nameplate drafts, test reports and O&M manuals supplied in English.
Qualified sources for silicon steel, copper, bushings and accessories secure stable lead times.
Technical questions and after-sales issues receive a qualified reply within one working day.
From core stacking to final dielectric testing, each step is controlled by documented work instructions and inspection checkpoints.












Engineers check ratings, standards, site altitude and ambient conditions.
GA drawing, nameplate and guaranteed losses confirmed with buyer.
Core, winding, drying and tanking with in-process QC records.
Full test report per unit; third-party witness testing welcome.
Export crating, impact recorders and complete shipping documents.
Certificate numbers are listed so your compliance team can verify them directly with the issuing bodies.
Certificate No. 62824Q6052R0S · valid 2024–2027.
Certificate No. 62824E6053R0S · valid 2024–2027.
Certificate No. 62824S6054R0S · valid 2024–2027.
Production capability, floorspace and quality inspection verified onsite by an independent third party.
Oil-immersed power transformer · No. 3N230310.JYTU038 · 2023–2028.
Oil immersed transformer · No. M.2025.206.C121882 · 2025–2030.
Dry type transformer · No. FQC2530404 · 2025–2030.
Compact substation · No. M.2025.206.C121884 · 2025–2030.
Equipment is configured for local grid codes, frequency (50/60 Hz), climate and installation practice in each market.
ANSI/IEEE pad mounted and pole mounted transformers for utilities, solar and commercial projects.
Distribution and power transformers for mining, utilities and high-altitude installations.
CE-certified IEC equipment, dry type transformers and compact substations.
High-ambient designs with enhanced cooling for desert and coastal environments.
Utility distribution, industrial parks and grid expansion programs.
Rural electrification, mining and compact substations for fast deployment.
FOB, CFR, CIF, EXW, FAS, FCA, CPT, CIP, DDP, DDU and express delivery.
T/T, L/C, D/P, D/A, escrow and other secure options agreed per contract.
USD, EUR, GBP, CAD, AUD, JPY, HKD, CHF and CNY.
A quick engineering comparison our application team uses with EPC contractors and utilities when shortlisting equipment.
| Transformer Type | Typical Rating | Installation | Best Application | Key Standards |
|---|---|---|---|---|
| Three Phase Pad Mounted | 45 – 5,000 kVA, up to 34.5 kV | Outdoor, ground pad, underground cable feed | Commercial sites, solar farms, data centers, campuses | IEEE C57.12.34, C57.12.28 |
| Single Phase Pad Mounted | 10 – 250 kVA | Outdoor, residential easements | Housing developments, rural underground loops | IEEE C57.12.38 |
| Oil Immersed Distribution | 30 – 2,500 kVA, 6 – 35 kV | Outdoor platform, pole or substation | Utility distribution, industrial plants, mines | IEC 60076-1/-2/-3 |
| Cast Resin Dry Type | 30 – 2,500 kVA, up to 35 kV | Indoor, close to the load | Hospitals, high-rises, tunnels, marine, fire-sensitive areas | IEC 60076-11 |
| Power Transformer | 35 – 500 kV class | Outdoor substation | Transmission, generation step-up, grid interconnection | IEC 60076, IEEE C57.12.00 |
| Compact Substation | 100 – 2,500 kVA, 10 – 35 kV | Outdoor, prefabricated enclosure | Renewables, urban networks, temporary or fast-track projects | IEC 62271-202 |
Ranges shown are typical production ranges. Ratings outside these values can be engineered on request.
Straight answers from our engineering and export departments.
Sharing these parameters lets our engineers return a compliant design and guaranteed losses without extra clarification rounds.
Send your datasheet or tender documents. A transformer engineer, not a sales script, will review it and respond within one working day.
[email protected]