Factory-Built Transformer Range

8 Reference Configurations for OEM Procurement

The eight export-ready references below show the manufacturing envelope of our transformer platform: distribution, pad-mounted, oil-immersed power and industrial supply configurations from 10 kVA to 31,500 kVA. For a dry-type-only bill of materials, submit your datasheet and our engineers will return a cast resin or VPI proposal with guaranteed losses, drawings and test plan. Product URLs are preserved for direct technical review.

CE / IEEE CE and IEEE standard 33kV oil immersed three phase transformer

CE/IEEE 33 kV S11 Three-Phase Transformer for Industrial Power

Oil-immersed industrial unit for projects requiring IEEE-style documentation and CE marking, with routine loss and dielectric testing.

33 kV class50/60 HzS11 low-loss
View specification
Distribution S11 three phase oil transformer for power distribution 10kVA to 50000kVA

10 kVA–50,000 kVA S11 Transformer for Power Distribution

Broad-range S11 platform for utility distribution, industrial plants and renewable interconnection with custom vector group and taps.

10–35 kVUp to 50 MVA50/60 Hz
View specification
CE S11 10kV 20kV 35kV 50kVA to 250kVA oil immersed distribution transformer

S11 10–35 kV, 50–250 kVA Oil-Immersed Distribution Transformer

Space-efficient distribution transformer for pole, platform or compact substation installation with sealed tank options.

50–250 kVA10–35 kV3-phase
View specification
Pad-Mounted Oil type pad mounted transformer 75kVA to 400kVA for power generation

Oil-Type Pad-Mounted Transformer, 10–35 kV

Tamper-resistant pad-mounted unit for underground distribution, commercial sites and generation projects.

75–400 kVAPad-mounted3-phase
View specification
CE Oil immersed three phase power transformer 100kVA to 1000kVA

100–1,000 kVA Oil-Immersed Power Transformer

Medium-capacity power transformer for industrial supplies, commercial buildings and utility distribution networks.

100–1,000 kVA10/20/35 kVPower supply
View specification
MV / HV MV HV three phase pad mounted transformer for industrial power supply

MV/HV Pad-Mounted Transformer for Industrial Supply

Industrial-grade pad-mounted transformer for 6–35 kV networks with custom bushings, fusing and enclosure finish.

6–35 kVMV/HVIndustrial
View specification
Heavy Duty 750kVA to 2500kVA MV HV pad mounted transformer

750–2,500 kVA MV/HV Pad-Mounted Transformer

High-capacity pad-mounted configuration for industrial power supply, plants and infrastructure projects.

750–2,500 kVA3-phaseHeavy duty
View specification
S11 30kVA to 31500kVA S11 three phase oil transformer 6kV to 35kV

30–31,500 kVA S11 Transformer for Power Distribution

Wide-range S11 oil transformer for distribution projects requiring custom impedance, tap range and loss guarantees.

30–31,500 kVA6–35 kVDistribution
View specification

The references above include related oil-immersed and pad-mounted ranges. For dry type cast resin or VPI transformers, send your single-line diagram, rating, ambient conditions and loss target through the quote button.

20+Years of team experience in transformer engineering
220 V–500 kVSupply envelope covering distribution to transmission class
6,847 m²Verified production floorspace inspected by TÜV Rheinland
50+R&D and technical engineers supporting OEM projects
211Qualified supply-chain partners for stable material allocation
24 hTarget engineering response for technical and after-sales queries
Search Intent & Engineering Reality

What Buyers Really Mean by “Custom OEM Dry Type Power Transformer Factories & Suppliers”

Buyers searching for custom OEM dry type power transformer factories and suppliers usually have a live electrical design and a risk to remove: fire load in a basement, oil containment in a dense urban site, a data-centre expansion with limited space, a hospital project with strict indoor safety requirements, or an OEM programme that needs a repeatable dry type platform across several markets.

They do not need another directory. They need a factory that can read a single-line diagram, challenge an incomplete datasheet, propose a compliant cast resin or VPI design, document no-load and load losses, pass routine tests, and ship with nameplates, drawings and O&M manuals that match the local grid code. That is the difference between a supplier listing and a manufacturing partner.

A dry type transformer is not automatically safer or more efficient in every project. Its advantage comes from removing liquid dielectric and reducing fire propagation risk in indoor or densely occupied areas. The trade-off is thermal management, enclosure design, acoustic treatment and first cost. The correct selection depends on ambient temperature, altitude, duty cycle, harmonic spectrum, IP rating, seismic requirement, local code and total cost of ownership.

Jiangsu Wisegj Power Co., Ltd. supports this decision process from Suzhou, China, with transformer engineering experience, in-house production control and export documentation for IEC and IEEE markets. Our product portfolio spans dry type transformers, oil-immersed transformers, pad-mounted transformers, power transformers, compact substations, switchgear, distribution boxes and voltage stabilizers from 220 V to 500 kV.

Jiangsu Wisegj Power factory and engineering team
Factory-based engineering support: specification review, drawings, routine testing and export packing.
Transformer testing laboratory with routine test equipment
Test reports are issued per serial number; third-party witness inspection can be arranged before shipment.
Customisation Levers

What “OEM Dry Type” Should Include in a Real RFQ

A dry type transformer quotation is only comparable when the design envelope is defined. These are the variables our engineers review before confirming losses, dimensions, weight and delivery.

Rating, Voltage & Vector Group

30–2,500 kVA dry type ranges are common; higher ratings are engineered on request. Primary voltages up to 35 kV, custom secondary voltages, Dyn11, Yyn0 and project-specific vector groups.

Cast Resin, VPI or Hybrid Winding

Insulation class F or H, temperature-rise limits, epoxy cast resin or vacuum pressure impregnation, copper or aluminium conductors, electrostatic shielding and harmonic-duty design.

Enclosure, IP Rating & Siting

IP20, IP31, IP54 or higher; indoor or outdoor enclosure; seismic bracing; ventilation louvres; cable entry from top or bottom; paint system matched to coastal, desert or industrial atmospheres.

Cooling & Thermal Management

AN or AF cooling, fan control logic, alarm and trip contacts, Pt100 sensors, winding and core temperature monitoring, acoustic limits and high-ambient derating.

Losses & Life-Cycle Cost

No-load and load-loss optimisation against your evaluation factors. For many utilities, a compliant offer is judged with loss capitalisation, not simply the lowest equipment price.

Documentation & Interface

GA drawings, nameplate drafts, loss guarantees, routine test reports, O&M manuals, cable boxes, busduct interfaces, MCCB or switchgear integration and bilingual labelling.

Procurement Trends

Dry Type Transformer Buying Trends to Put Into Your Next RFQ

The market is moving away from “cheapest kVA” towards auditable lifecycle value. These six trends are shaping supplier selection for utilities, EPCs, data centres and industrial OEMs.

Loss Capitalisation Replaces Price-Only Comparison

Evaluate offers with a formula such as bid price + A × no-load loss (W) + B × load loss (W), where A and B are present-value factors from your utility or finance team. This exposes inefficient designs that look inexpensive on day one.

Fire Safety and Indoor Siting

Basements, tunnels, hospitals, airports and high-rise buildings increasingly specify dry type transformers to avoid oil containment and fire propagation. The RFQ should state enclosure, ventilation and acoustic limits.

Data Centre and Renewable Power Quality

Harmonic-rich loads, high duty cycles and constrained plant rooms require K-factor or harmonic-duty review, careful temperature rise selection and documented short-circuit withstand capability.

Digital Monitoring and Lifecycle Data

Pt100 sensors, winding temperature indication, fan control and remote alarm contacts are becoming standard in critical facilities. The supplier should provide a clear terminal diagram and signal list.

Traceability and Certificate Verification

Procurement teams now ask for certificate numbers, test reports and inspection records before releasing payment. Suppliers should make ISO, CE, routine-test and third-party inspection documents easy to audit.

Prefabricated and Modular Substations

Factory-assembled enclosures reduce site labour and commissioning risk. A dry type transformer, MV switchgear and LV distribution can be integrated into a compact substation for faster energisation.

Technology Development

Where Dry Type Power Transformer Design Is Heading

The next purchasing cycle will reward suppliers who can document thermal performance, losses, recyclability and digital interfaces — not only nameplate kVA.

Higher Efficiency, Lower Losses

Improved core steel, optimised winding geometry and loss evaluation are driving designs that meet stricter efficiency rules without oversizing the enclosure.

Safer Insulation Systems

Cast resin and VPI systems continue to improve in thermal class, partial-discharge behaviour and fire performance. Eco-friendly materials and recyclability are now part of supplier discussions.

Smart Sensors as Standard

Temperature monitoring, fan control and alarm contacts are moving from options to standard deliverables for critical infrastructure and data-centre projects.

Integrated Substations

Dry type transformers are increasingly delivered inside prefabricated enclosures with MV switchgear, LV distribution and protection for faster site installation.

Higher Voltage and Larger Ratings

Dry type designs up to 35 kV and beyond are specified for renewable collection, industrial plants and urban substations. For larger ratings, thermal design and enclosure ventilation become the limiting factors, so early supplier consultation is essential.

Total Cost of Ownership

The winning offer is increasingly the one with the lowest evaluated cost after adding loss capitalisation, maintenance access, spare-part availability, lead time and lifecycle documentation — not simply the lowest purchase order value.

Selection Guide

Dry Type vs Oil Immersed vs Pad-Mounted: Procurement Comparison

Use this table for early-stage shortlisting. Final selection must be confirmed against local fire code, utility standards, ambient conditions and your loss evaluation method.

Criterion Dry Type / Cast Resin Oil-Immersed Distribution Pad-Mounted Transformer
Typical sitingIndoor, basement, tunnel, hospital, data centre, high-riseOutdoor platform, pole, industrial yard, compact substationOutdoor ground pad, underground cable feed, commercial campus
Fire and oil containmentNo liquid dielectric; lower fire load in many indoor designsRequires oil containment and fire separation per local codeOil-filled unit inside tamper-resistant enclosure; containment design required
Typical rating30–2,500 kVA, up to 35 kV, larger on request30–2,500 kVA, 6–35 kV distribution45–5,000 kVA, up to 34.5 kV class
Maintenance accessInspection of windings, fans, filters and temperature devicesOil testing, sealing inspection, tap changer checks where fittedEnclosure access, fuse and switch inspection, oil sampling
First costUsually higher than equivalent oil-immersed units at smaller ratingsCost-effective for conventional outdoor distributionHigher than pole-mounted due to enclosure and accessories
Best fitIndoor safety, urban density, fire-sensitive buildings, clean roomsUtility distribution, industrial plants, renewable projectsUnderground residential and commercial distribution

Illustrative Buyer Weighting for Indoor Distribution Projects

This is an illustrative procurement weighting, not a standard. Use it to start a scoring discussion with your engineering and finance teams.

Fire safety / code30%
Life-cycle cost25%
Footprint / layout15%
Lead time15%
Monitoring / digital10%
Local service5%

Information Gain: Practical RFQ Data That Avoids Re-Design

  • Rated power (kVA) and frequency
  • Primary and secondary voltage
  • Vector group and impedance
  • Tap range and tap changer type
  • Ambient temperature, altitude and humidity
  • Enclosure IP rating and installation location
  • No-load and load-loss limits
  • Applicable standard: IEC 60076-11 or IEEE C57.12.01
Wisegj company facility and production overview
Suzhou-based manufacturer and exporter with an auditable production base.
Factory Advantages

How Wisegj Reduces Custom OEM Transformer Procurement Risk

Jiangsu Wisegj Power Co., Ltd. is a manufacturer and exporter based in Suzhou, Jiangsu, China, serving utilities, EPC contractors and industrial buyers across North America, South America, Western Europe, Southeast Asia, the Middle East and Africa. The product portfolio covers 220 V to 500 kV and includes pad-mounted transformers, oil-immersed transformers, dry type transformers, power transformers, compact substations, high and low voltage switchgear, distribution boxes and voltage stabilizers.

Our engineering team brings more than 20 years of hands-on transformer experience. Every project is reviewed by engineers before quotation, produced under documented ISO quality control and shipped with routine test reports. Production floorspace, capability and inspection processes have been verified onsite by TÜV Rheinland, an independent third-party inspection body.

  • Own production base with complete industry certificates
  • 50+ R&D and technical engineers
  • Supplier to Fortune 500 companies
  • 24-hour pre-sale and after-sale response target
  • OEM, ODM, design-based and sample-based customisation
  • Finished-product inspection on every unit
  • Certified management systems: ISO 9001, ISO 14001, ISO 45001
  • Export packing, shock indicators and full shipping documentation
Quality & Compliance

Certificates, Testing and Documentation That Can Be Audited

Certificate numbers are provided so your compliance team can verify them directly with the issuing bodies. Routine test reports are issued per serial number, and third-party witness inspection is welcome.

CE certificate for dry type transformer FQC2530404

CE · Dry Type Transformer

Certificate No. FQC2530404 · valid for applicable dry type transformer configurations. Confirm model scope before order.

ISO 9001 quality management system certificate

ISO 9001 Quality Management

Certificate No. 62824Q6052R0S · management system certification supporting design, production and inspection control.

ISO 14001 environmental management system certificate

ISO 14001 Environmental Management

Certificate No. 62824E6053R0S · supports environmental control in manufacturing and export operations.

Routine Tests Before Shipment

Winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied voltage, induced voltage, insulation resistance, plus oil dielectric strength for liquid-filled units. Partial discharge and temperature-rise type-test reports can be provided for dry type projects when specified.

Design Review & Drawing Approval

Engineers check ratings, standards, site altitude, ambient conditions and seismic requirements. GA drawings, nameplate drafts and guaranteed losses are confirmed with the buyer before production release.

Complete Export Documentation

Test reports, O&M manuals, packing lists, certificate packs and nameplate language are prepared to the purchase order. Seaworthy packing and impact recorders are available for long ocean routes.

Production Control

From Specification Review to Export Packing

A repeatable five-stage workflow helps keep custom OEM dry type and oil-immersed transformer projects comparable, inspectable and on schedule.

Specification Review

Ratings, standards, site altitude and ambient conditions checked by engineers.

Drawing Approval

GA drawing, nameplate and guaranteed losses confirmed with the buyer.

Controlled Production

Core stacking, winding, drying and tanking with in-process QC records.

Routine Testing

Full test report per unit; third-party witness testing can be arranged.

Packing & Shipping

Export crating, impact recorders and complete shipping documents.

Applications

Where Custom Dry Type and OEM Transformer Solutions Fit

Selection is driven by installation environment, duty cycle and local code. These application modules show the most common project profiles.

Commercial Buildings & Hospitals

Indoor dry type transformers reduce liquid-dielectric risk in basements and occupied buildings. Enclosure, acoustic and ventilation design must be agreed early.

Data Centres & Critical Facilities

Harmonic duty, high availability and monitoring requirements make dry type or compact substation solutions attractive where indoor siting is required.

Solar, Wind & Renewable Projects

Collection substations and inverter interfaces require documented losses, custom vector groups, corrosion protection and coordinated protection settings.

Industrial Plants & Mining

High-ambient, dusty or coastal environments require enclosure, paint and cooling choices that protect the transformer over a long service life.

Residential & Urban Distribution

Pad-mounted and single-phase or three-phase distribution transformers support underground loops, subdivisions and municipal networks.

Fast-Track & EPC Projects

Prefabricated compact substations and factory-tested transformers reduce site labour, commissioning time and interface risk.

Procurement FAQ

Questions Buyers Ask About Custom OEM Dry Type Transformers

Direct answers from the engineering and export perspective. Project-specific requirements should always be confirmed against the final datasheet.

Are you a dry type power transformer factory or a trading company?

Jiangsu Wisegj Power Co., Ltd. is a manufacturer and exporter based in Suzhou, China. Core design review, production control, testing and export documentation are managed through our transformer platform. Our product range covers dry type, oil-immersed, pad-mounted and power transformers, compact substations and switchgear from 220 V to 500 kV.

Can you build a custom OEM dry type transformer to our datasheet?

Yes. We support OEM, ODM, design-based and sample-based customisation. Typical customisation includes ratings, vector group, impedance, tap range, enclosure IP rating, bushing configuration, cooling method, winding material, temperature-rise limits, loss targets, paint colour and nameplate language.

Which standards and certificates apply?

Transformers are designed and tested to IEC 60076 series standards or ANSI/IEEE C57.12 series standards depending on the destination market. Our dry type transformer CE certificate is FQC2530404; management systems include ISO 9001 No. 62824Q6052R0S, ISO 14001 No. 62824E6053R0S and ISO 45001 No. 62824S6054R0S. Applicable model scope should be confirmed with the quotation.

What are typical lead times for a custom order?

Lead time depends on rating, enclosure, accessories, material allocation and drawing approval status. Standard distribution units often follow a shorter cycle, while larger dry type units, compact substations or projects requiring type-test reports and witness inspection require engineering and test scheduling. The quotation should state a lead time tied to the approved GA drawing, not a generic catalogue estimate.

Which tests are performed before shipment?

Routine tests typically include winding resistance, voltage ratio and vector group, impedance and load loss, no-load loss and current, applied voltage, induced voltage and insulation resistance. For liquid-filled units, oil dielectric strength is checked. For dry type projects, partial discharge and temperature-rise type-test reports can be provided when specified. Third-party witness inspection can be arranged.

Can you optimise losses to meet our efficiency regulation?

Yes. Provide your required efficiency class, loss limits or loss-evaluation factors. We can quote alternative designs with different no-load and load-loss combinations so your team can compare first cost against lifecycle cost. This is especially important where the utility applies loss capitalisation in bid evaluation.

How do you handle export packing and logistics?

Transformers are prepared with export packing suitable for the agreed transport mode. Seaworthy crating, shock indicators, lifting points, rust prevention and complete shipping documents are available. We work with Incoterms including EXW, FOB, CFR, CIF, FCA, CIP, CPT and DDP where commercially applicable.

Can you supply oil-immersed and pad-mounted transformers as well?

Yes. The eight reference products on this page cover oil-immersed distribution, pad-mounted and industrial power transformer configurations from 10 kVA to 31,500 kVA. If your project requires a dry-type-only solution, we can quote that separately against your single-line diagram and technical specification.

What payment terms and currencies are accepted?

Payment methods such as T/T, L/C, D/P and D/A can be discussed based on contract value and destination. Major currencies including USD, EUR, GBP, CAD, AUD and others can be quoted. Final terms are confirmed in the commercial proposal.

Send Your Dry Type Transformer Datasheet for Engineering Review

Share your single-line diagram, required kVA, primary and secondary voltage, vector group, ambient conditions, enclosure IP rating, loss target and delivery schedule. Our engineers will return a compliant custom OEM dry type power transformer proposal with guaranteed losses, outline drawing, test plan and export documentation requirements.

Technical information on this page is provided for preliminary sourcing and engineering discussion. Final design, certification scope, losses, dimensions, tests and delivery schedule must be confirmed in the approved datasheet and purchase order against the applicable local grid code and project specification.